Multi-para Monitor KPM-B100 is a pre-configured bedside monitor equipped with 12.1-inch screen display with 9 waveforms. Advanced capabilities like ECG analysis, OxyCRG dynamic, calculation of drug concentration and trend reporting improves utility and user convenience. Multi-optional display of monitor profiles enables easy to read screen from across the room.
Ask Quote
Standard Parameter | 5‐lead ECG, RESP, HR, NIBP, SpO2(F‐5), 1‐TEMP, PR |
---|---|
Patient Groups | Neonate, Pediatric, Adults |
Trace | 9 waveform (ECG,SpO2, RESP) |
ECG Lead Mode | 5–lead (R, L, F, N, C) for leads I, II, III, V, aVR, aVF, aVL |
ECG Waveform | 3 and 7 channel selectable |
ECG Gain selection | 0.5mm/mv 1mm/mv 2mm/mv |
ECG Sweep Speed | 12.5 mm/s 25 mm/s 50 mm/s |
Heart Rate range | Adult : 15 ~ 300 bpm Neonate /Pediatric : 15 bpm ~ 350 bpm Alarm range : 15 ~ 350 bpm |
ECG Accuracy | +1 bpm |
ECG Resolution | 1 bpm |
Protection | withstands 4000VAC/50 voltage isolation |
S‐T segment analysis | Range : -2.0 mV ~ +2.0 mV Accuracy: ‐0.8mV ~ +0.8mv Error: +0.02Mv |
Scaling | 1mv, +3% |
SpO2 Measurement range | 0% ~ 100% Alarm range : 0% ~ 100% |
SpO2 Accuracy | ±2 % (70 % – 100 %) 0 – 69% unspecified |
SpO2 Pulse Rate | Range : 20bpm ~ 300bpm Resolution: 1bpm Error: +1bpm |
NIBP Method | Digital Automatic Oscillometric |
NIBP Operation Mode | Manual/Automatic/Continuous for Systolic, Diastolic and Mean |
Auto Measurement | Adjustable Duration : 1 ~ 480 mins |
Range Of Systolic Pressure | Adult: 40 ~ 270mmHg Pediatric: 40 ~ 220mmHg Neonate: 40 ~ 135 mmHg |
Range Of Diastolic Pressure | Adult: 10 ~ 215 mmHg Pediatric: 10 ~ 150 mmHg Neonate :10 ~ 100 mmHg |
Over‐pressure Protection | Double safety protection |
Respiratory Method | Thoracic impedance |
Respiratory Measurement range | Adult: 7 ~ 120 rpm Neonate/Pediatric: 7 ~ 150 rpm |
Apnea Alarm | 10s ~ 40s |
Respiratory Resolution | 1 rpm |
Respiratory Accuracy | ±2 bpm |
Temp Measurement range | 5 ℃ ~ 50 ℃ |
Average Measuring Time | < 10 sec |
Temp Resolution | 0.1℃ |
Temp Accuracy | ± 0.1℃ |
Display | 12.1’’color TFT |
Resolution | 800 x 600 dot pixels |
Trend | 5 s/piece, 8 hours 5min/piece, 1000 hours |
Alarm | User‐adjustable 3‐level Audio-visual alarm. |
Safety Standard | Class I, type CF |
Working Temperature | 0 ~ 40℃ |
Relative Humidity | ≤ 85 % |
Power Supply | AC 100 ‐ 240 V, 50/60 Hz |
Battery | Rechargeable Lead acid cell, 12 V/4 Ah |
Storage | NIBP : 1000 groups Alarms : 200 groups Holographic waveform : 1 hour |
Dimension | 280 × 420 × 480 mm |
Weight | 5 Kgs |